  • Handheld Water Quality Meters

    LAQUA PC220 - HORIBA, Ltd.

    - Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty

  • Handheld Water Quality Meters

    LAQUA EC220 - HORIBA, Ltd.

    - Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Automatic / manual temperature compensation and temperature calibration function- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- °C & °F temperature readings- With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto stable, auto hold, and real-time measurement modes- Auto shut-off (programmable: up to 30 minutes)- Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting the meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Powered by 2 x AA batteries - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Packaged with electrode and calibration solutions in carrying case- 3 years meter warranty

  • Optical Meters

    Gamma Scientific Inc.

    The Gamma Scientific range of light meters includes handheld and benchtop models.  Configuration options include a wide range of sensors and calibrations in units including:  Luminous Flux (lumens) or Radiant Flux (Watts),  Illuminance (lux, foot-candle) or Irradiance (W/cm2 ), Luminous Intensity (candela) or Radiant Intensity (W/sr),  Luminance (cd/m2 , foot-Lambert) or Radiance (W/m2 sr),  or Pulse Energy (Joules). Cooled sensors and reference standard detectors are also available.

  • Hydrophone

    RESON TC4013 - Teledyne Marine RESON B.V.

    ​The TC4013 offers a usable frequency range of 1Hz to 170kHz and a high sensitivity relative to its size. It further-more provides uniform omnidirectional sensitivities in both horizontal and vertical planes up to high frequencies.The TC4013 is an excellent transducer for making absolute sound measurements and calibrations within a broad frequency range. It can also be applied as an omnidirectional reference projector.The overall characteristics makes TC4013 extremely applicable for laboratory as well as industrial uses.​

  • Vibration Calibrator

    SV 111 - SVANTEK Sp. z o.o.

    SV 111 vibration calibrator is the State of the Art instrument designed for human vibration measurements according to ISO 8041. The design of the calibrator is based on the triaxial reference accelerometer and microprocessor controlled shaker. These both features assure excellent stability of the calibration levels and their frequency independently from mass of the testing object, like also indicate improper test object fixing by monitoring of shaker vibration in all three axis simultaneously.

  • Portable Battery Coolant/Glycol Refractometer with ATC (°C)

    Extech RF41 - Extech Instruments Corporation

    Refractometer measures the Propylene/Ethylene Glycol freezing point from -50 to 0°C and the Specific Gravity of battery acid from 1.11 to 1.30 and provides a quick reference of battery charge condition. Requires only 2 or 3 drops of solution for fast and accurate readings. Automatic Temperature Compensation provides repeatable measurements on an easy to read scale. Prism and lens with a simple focus adjustment. Includes carrying case and calibration screwdriver.

  • Selective Level Meter

    Model SLM620 - Aplab Limited

    - Digital Synthesized Local Oscillator- Two Selective Bandwidths : 20Hz, 3.1KHz- Wideband, Low Noise and Low Distortion Measurements- dB/dBm Operation- High Frequency Stability- Internal Calibration Facility- Recorder Outputs- Frequency Tracking Facility with Level Oscillator SLG620- Storage of Nine Spot Frequencies- Reference Level Set Facility- Autotune Feature- Operates on AC Mains or Internal Rechargeable Battery- Built in charger- Graphic LCD Display with Backlight

  • Reference Temperature Sensors

    AMETEK Sensors, Test & Calibration

    Our reference sensors can be used as your daily working-reference sensors in laboratory or field calibration applications. A large selection of types are available, including; straight, 90 degree angle, 4 mm or 1/4”. The superior design and specifications combined with a long history of reliability and low drift have made the STS probes the working-standard in many EN/IEC 17025 accredited laboratories worldwide. The DLC sensors are a part of our patented Dynamic Load Compensation system.

  • Piston Gauges

    Fluke Calibration

    Fluke Calibration piston gauges provide reference level primary pressure measurements for some of the top laboratories in the world. Our piston gauge lineup includes models that offer full automation. Our primary level pressure balances utilize a fundamental equation to determine generated pressure with very low levels of uncertainty. Piston gauge models include PG7000 and PG9000 DHI systems with AMH automated mass handling and other automation hardware; 2465, 2468, 2470 and 2485 Ruska piston gauges and 24xx differential pressure cell and other piston gauge accessories; FPG8601 DHI very low pressure standard; 2482 Ruska differential pressure standard. Standard pressure calibration.

  • Acoustic Calibrators

    Castle Group Ltd.

    When you're ready to take noise measurements, it's strongly recommended that you perform a field calibration using an Acoustic Calibrator. You should calibrate your sound meter before you start to measure, and then once you've finished you should perform a reference check against the calibrator and make note of any drift that has occured. You can find out more about performing Field Calibrators by reading this post and watching a short video.

  • Temperature Calibrators

    Fluke Calibration

    Ensuring process temperature accuracy involves calibrating not only the system’s electronic temperature signals, but also the very temperature sensors that initiate those signals. Rugged Fluke handheld temperature calibrators source and measure RTDs and thermocouples, power transmitters, and store data. Fluke Calibration temperature sources cover temperatures from -45 °C to 1200 °C and include handheld, portable, and benchtop calibrators. Infrared thermometer calibrators and reference measurement thermometers ensure every necessary tool is available to you.

  • Conformance Calibration Standard Test Card for ISO/IEC Data Matrix and GS1 DataMatrix Symbol Verifiers

    AI-CCS-DM-G Rev A - Applied Image, Inc.

    This precision 2D barcode Conformance Calibration Standard Test Card is the first 2D test card to provide ALL 12 of the Primary Reference Symbols specified by ISO 15426-2 for barcode verifiers. They are sized from 0.5mm to 0.2mm so that all the symbol sizes specified in Annex A.3.1 can be tested. Symbols 1-4 are GS1 DataMatrix symbols, while symbols 5-12 are ISO/IEC Data Matrix symbols consistent with the ISO/IEC 16022 standard. The card also includes four calibrated reflectance patches.

  • Single-Channel Voltage Output D/A Converters

    Analog Devices Inc.

    Analog Devices offers a broad portfolio of single-channel voltage D/A converters, which includes many leading products in performance and package size, with resolutions from 8-bit to 20-bit, low power, and a serial SPI, parallel, or I2C interface. Within the industry’s smallest packages, we offer more functionality within smaller board and module sizes. The integration of a precision reference minimizes board area and costs, eliminates the need of calibration, and reduces the number of external components to simplify the design stage.

  • True RMS RF Millivoltmeter

    3440A - Ballentine Laboratories, Inc.

    The 3440A measures the true rms of low level RF and microwave signals to over 1GHz. High rms accuracy, traceable to NIST, is assured regardless of waveshape. Common calibration errors are eliminated through temperature compensation of the probe detector diodes; double shielding protects the interchangeable probes from rough handling and pickup. Relative gain or loss measurements are simplified by a 0 dB reference adjustment. DC output proportional to the ac input is provided for analog recorders and to allow operation as an ac-dc converter.

  • EcoTestr™ pH1 Waterproof Pocket Tester

    OAKTON Instruments

    The economical, simple-to-use pH tester measures pH levels and temperatures quickly, displaying them both simultaneously on a large dual-line LCD. It has a pH range from 0 to 14 with an accuracy of ±0.1 pH. The tester features up to three pH calibration points with auto NIST and US buffer recognition. Additional features include a long-lasting durable electrode with polymer reference electrolyte; status icons for measurement stability, calibration, and battery life; and self-diagnostics. The IP67-rated housing features an easy-to-grip design and floats if accidentally dropped in water when sensor cap is on. The tester, powered by four AAA batteries, can operate up to 400 hours continuously. The unit will auto power-off after 8 minutes of nonuse to conserve power.